Instructions for use of rat vasoactive intestinal peptide (VIP) enzyme-linked immunoassay kit

Instructions for use of rat vasoactive intestinal peptide (VIP) enzyme-linked immunoassay kit
This kit is for research use only.
Detection range: 48T
5ng / L -160ng / L
purpose of usage:
This kit is used to determine the content of vasoactive intestinal peptide (VIP) in rat serum, plasma and related liquid samples.
Experimental principle
This kit uses the double antibody sandwich method to determine the level of rat vasoactive intestinal peptide (VIP) in the specimen. Microporous plates were coated with purified rat vasoactive intestinal peptide (VIP) antibody to make solid-phase antibodies, and vasoactive intestinal peptide (VIP) was added to the monoclonal antibody-coated microwells in turn, followed by HRP-labeled vasoactivity The intestinal peptide (VIP) antibody binds to form an antibody-antigen-enzyme-labeled antibody complex, and after thorough washing, the substrate TMB is added for color development. TMB is converted into blue under the catalysis of HRP enzyme, and into the final yellow under the action of acid. The color depth is positively correlated with the vasoactive intestinal peptide (VIP) in the sample. The absorbance (OD value) was measured with a microplate reader at a wavelength of 450 nm, and the concentration of rat vasoactive intestinal peptide (VIP) in the sample was calculated by a standard curve.
Kit composition
1
20 times concentrated washing liquid
20ml × 1 bottle
7
Stop solution
3ml × 1 bottle
2
Enzyme reagent
3ml × 1 bottle
8
Standard product (320ng / L)
0.5ml × 1 bottle
3
Enzyme coated plate
12 holes × 4 strips
9
Standard dilution
1.5ml × 1 bottle
4
Sample diluent
3ml × 1 bottle
10
Instructions
1 serving
5
Developer A liquid
3ml × 1 bottle
11
Sealing film
2 sheets
6
Developer B liquid
3ml × 1 / bottle
12
sealed bag
1
Specimen requirements
1. Specimens are extracted as soon as possible after collection, and extraction is performed according to relevant literature, and experiments should be conducted as soon as possible after extraction. If the test cannot be performed immediately, the specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided
2. The samples containing NaN3 cannot be detected because NaN3 inhibits horseradish peroxidase (HRP) activity.
Steps
1. Dilution of standard products: This kit provides one original standard product. The user can perform dilution in a small test tube according to the following chart.
160ng / L
Standard No. 5
150μl of original standard is added to 150μl standard dilution
80ng / L
Standard 4
150μl Standard No. 5 is added to 150μl standard dilution
40ng / L
Standard 3
150μl Standard No. 4 is added to 150μl Standard Diluent
20ng / L
Standard No. 2
150μl Standard No. 3 is added to 150μl Standard Diluent
10ng / L
Standard 1
150μl Standard No. 2 is added to 150μl Standard Diluent
2. Sample addition: set up blank wells (the blank control wells do not add samples and enzyme reagents, the rest of the operation is the same), standard wells, sample wells to be tested. Accurately add 50μl of the standard on the enzyme-coated plate, add 40μl of sample diluent to the sample well, and then add 10μl of the sample to be tested (the final dilution of the sample is 5 times). Add the sample and add the sample to the bottom of the well of the microplate, try not to touch the wall of the well, shake gently to mix.
3. Incubation: Seal the plate with a sealing plate and incubate at 37 ° C for 30 minutes.
4. Mixing solution: dilute 20 times concentrated washing liquid with distilled water 20 times and reserve.
5. Washing: Carefully peel off the sealing film, discard the liquid, spin dry, fill each well with the washing liquid, let it stand for 30 seconds and then discard, repeat 5 times and pat dry.
6. Add enzyme: add 50μl of enzyme label reagent to each well, except blank well.
7. Incubation: The operation is the same as 3.
8. Washing: The operation is the same as 5.
9. Color development: add 50μl of developer A to each well, and then add 50μl of developer B, mix gently, and develop at 37 ° C for 15 minutes in the dark.
10. Termination: Add 50μl of stop solution to each well to stop the reaction (at this time the blue will turn to yellow).
11. Determination: Measure the absorbance (OD value) of each well in sequence with the blank air conditioner at zero and 450 nm wavelength. The measurement should be carried out within 15 minutes after adding the stop solution.
Summary of operating procedures:
Instructions for use of rat vasoactive intestinal peptide (VIP) enzyme-linked immunoassay kit
Calculation
Taking the concentration of the standard as the abscissa and the OD value as the ordinate, draw a standard curve on the coordinate paper, and find the corresponding concentration from the standard curve according to the OD value of the sample; then multiply it by the dilution factor; Calculate the linear regression equation of the standard curve with the OD value, substitute the OD value of the sample into the equation, calculate the sample concentration, and multiply it by the dilution factor to obtain the actual concentration of the sample.
Precautions
1. The kit should be equilibrated at room temperature for 15-30 minutes before being taken out of the refrigerated environment. If the enzyme label coated plate is unopened, the strip should be stored in a sealed bag.
2. Crystals may be precipitated in the concentrated washing liquid, which can be heated and dissolved in a water bath during dilution, and the results will not be affected during washing.
3. The sampler should be used at each step of sample addition, and the accuracy should be regularly checked to avoid test errors. It is best to control the sampling time within 5 minutes. If there are many specimens, it is recommended to use a volley gun to add samples.
4. Please make a standard curve at the same time of each measurement, it is best to make a double hole. If the content of the test substance in the specimen is too high (the OD value of the sample is greater than the OD value of the first well of the standard well), please first dilute it with a certain multiple (n times) of the sample diluent and then determine it. When calculating, please multiply the total dilution Multiple (× n × 5).
5. The sealing film is limited to one-time use to avoid cross-contamination.
6. Please keep the substrate away from light.
7. Strictly follow the instructions, and the test results must be determined by the microplate reader.
8. All samples, washing liquids and various wastes should be treated as infectious agents.
9. The components of different batches of this reagent shall not be mixed.
10. If there is any difference with the English manual, the English manual shall prevail.
Storage conditions and validity period
1. Kit storage :; 2-8 ℃.
2. Validity: 6 months
Instructions for use of rat vasoactive intestinal peptide (VIP) enzyme-linked immunoassay kit

Appearance and packaging of wine play an important role for the success of the product.  Lanker pack have been providing durable and innovative wine packaging Spout Pouch, which does not restrict itself to making sure the product remain fresh and provide long shelf life, but also to grab the attention of the potential consumers and to convince them to buy what you place in the market.

Our wine  spout pouches  which provide easy to pour and fill application of wine so our pouches are more convenient, flexible and leakage proof than the plastic or cans or other traditional wine packaging .We offer wine spout pouches in several sizes, patterns and colours with stock and custom printed selections as per requirements.You can customize them based on your requirements.

Wine Pouch

Wine Spout Pouch,Wine Packaging Spout Pouch,Wine Bag With Spout Tap,Stand Up Wine Spout Pouch

Lanker Pack Group Limited , https://www.lankerflexible.com